Original Articles Open access

Effects of fixed compared to automatic CPAP on sleep in Obstructive Sleep Apnoea Syndrome

Authors

  • O. Resta – articles in this journal Corresponding author Email Centro Universitario Disturbi Respiratori nel Sonno; Dipartimento di Metodologia Clinica e Tecnologie Medico - Chirurgiche; Facoltà di Medicina e Chirurgia - Università degli Studi di Bari, Italy.
  • P. Carratù – articles in this journal Centro Universitario Disturbi Respiratori nel Sonno; Dipartimento di Metodologia Clinica e Tecnologie Medico - Chirurgiche; Facoltà di Medicina e Chirurgia - Università degli Studi di Bari, Italy.
  • A. Depalo – articles in this journal Centro Universitario Disturbi Respiratori nel Sonno; Dipartimento di Metodologia Clinica e Tecnologie Medico - Chirurgiche; Facoltà di Medicina e Chirurgia - Università degli Studi di Bari, Italy.
  • T. Giliberti – articles in this journal Centro Universitario Disturbi Respiratori nel Sonno; Dipartimento di Metodologia Clinica e Tecnologie Medico - Chirurgiche; Facoltà di Medicina e Chirurgia - Università degli Studi di Bari, Italy.
  • M. Ardito – articles in this journal Centro Universitario Disturbi Respiratori nel Sonno; Dipartimento di Metodologia Clinica e Tecnologie Medico - Chirurgiche; Facoltà di Medicina e Chirurgia - Università degli Studi di Bari, Italy.
  • O. Marrone – articles in this journal Consiglio Nazionale delle Ricerche; Istituto di Biomedicina e Immunologia Molecolare “A. Monroy”; Sezione di Fisiopatologia Respiratoria - Palermo, Italy.
  • G. Insalaco – articles in this journal Consiglio Nazionale delle Ricerche; Istituto di Biomedicina e Immunologia Molecolare “A. Monroy”; Sezione di Fisiopatologia Respiratoria - Palermo, Italy.
Published
30 September 2004
Section
Original Articles

Abstract

Background: Automatic CPAP has been developed to improve CPAP efficiency and compliance. Continually matching the effective pressure may be associated to more frequent arousals that could disturb sleep. The aim of the present study was to compare sleep architecture after one month’s home therapy with CPAP or with an AutoCPAP device. Methods: Twenty OSAS patients (18 M / 2 F) after polysomnographic study with CPAP titration received either an automatic (AutoSet T, ResMed, Sydney, Australia) or a fixed level CPAP machine in a random, single blind fashion for one month. At the end of the home treatment period polysomnography was repeated while CPAP was administered by the same machine used at home. Results: There was no significant difference between groups in terms of age (50.0 vs 45.5, NS), sex, BMI (38.3 vs 35.1, NS), RDI (45.4 vs 48.0, NS), and CPAP effective level (9.8 vs 10.8, NS). After one month of therapy the correction of sleep respiratory disturbances and of sleep structure was satisfactory in both groups. No difference in any polysomnographic variable or in subjective sleepiness was found at re-evaluation. Conclusions: The results of this study demonstrate that on average CPAP administered by a fixed CPAP machine and by the AutoSet T autoCPAP device has similar effects in improving respiratory function during sleep, nocturnal sleep architecture, and subjective daytime sleepiness after a one-month therapy. As autoCPAP devices are more expensive than fixed CPAP machines, their prescription should be considered only after a clear demonstration of an increase in compliance to treatment by these devices.

Metrics

Citations and online attention from Dimensions, Altmetric and PlumX.